Technische specs

Technische specs

Location loading dock

Indoor Loadingdock with Dock leveler. Secured parking space for one truck, a single-decker tourbus or 4 medium sized cars. Max vehicle height is: 3.95m (13 ft)

Loading dock is to be found here:
Map Loadingdock

Duycker backline

Ludwig Element  Drumkit
1 x Kick 22 ”
1 x Racktom 10 “
1 x Racktom 12 “
1 x Floortom 14 “
Hi-hatt 14”, drumkruk, pedalen en 2 bekkenstands
1 x Snare 14 ”
Cymbals  1 x Crash 16 “, 1 x Crash 18 “ 1 x Ride 20 ” 

Bass Amp & Cabinet:
1 x Hartke LH 1000 bas versterker
1 x Hartke HX410 bas speakerkabinet

Guitar Amps & Cabinets:
2 x Bugera 6262 INFINIUM gitaarversterker top
2 x Bugera 412H-BK gitaar speakerkabinet

Houserider bands main hall


Houserider bands main hall PDF

Tel: 023-5623310
E-mail: info@duycker.nl

Capacity
Main hall: 750

Max Sound Level  
103 dB(A)

Stage
Permanent stage: 14,00 x 8,50 m
Side stage left & right: 2,50 m
Height: 1 m.

Clearance
11,50 M

Powersupply
CEE-form 2 phase + earth
4 x 2 phase 32 A (Sound)
8 x 2 phase 16 A (Sound)
2 x  32 A CEE (norm IEC 60309) (Light)
1 x 125 A CEE (norm IEC 60309)

Access
Indoor Loadingdock with Dock leveler. Secured parking space for one truck, a single-decker tourbus or 4 medium sized cars. Max vehicle height is: 3.95m (13 ft)

Setup and sound check time
Standard time for setup and soundcheck for the main act is 2 hours before doors. In case of more than one opening act: only the first act will get a quick soundcheck, all other acts will line-check during changeover.

Stagehands
We do not provide stagehands, but we have a very helpful crew that will help you out whenever they can!

Hall expenses
Fixed expenses including; standard house P.A and Lights, standard promotion, standard crew consisting of 1 audio engineer, 1 lighting engineer and standard security.

Payment                                     
Duycker needs a copy of the pasport of all preforming artists to make payment possible.


P.A. Specifications MAIN HALL

Front of House      
1      DiGiCo SD8
1      Lexicon PCM92
1      CD player

Speakers
14    Martin Audio W8LCi
2      Martin Audio W8LCdi
6      Martin Audio WS218x

Amplifiers                                       
3      Martin Audio 6.8Q 4 x 1600W High & Mid
3      Powersoft K6        2 x 2500W 4 Ohm Low
2      Powersoft K10      2 x 4000W 4 Ohm Sub

Monitors
1      DiGiCo SD8
10    Synco CW 152 Floor monitors
1      Synco SW 152 Drum fill
2      Synco Quad Mon Rack
1      Synco Dual Mon Rack
1      Synco Single Mon Rack

Microphones / DI’s 
6      Shure SM58
6      Shure SM57
2      Shure Beta 58
2      Shure Beta 57
2      Shure Beta 87A
1      Shure Beta 91
2      AKG C214
2      Neumann KM184
1      AKG C451E
4      Sennheiser E904
3      Sennheiser MD421
6      Radial Pro48 Active
3      Radial ProDI Passive
2      Radial PROAV1
1      Radial Twin Isolator

Light specifications main hall

 

Duycker lightspecs Main Hall 17-01-2017
Patchview Main Hall 17-01-2017

Last edited 18‐01‐2017 (this rider cancels any previous versions)
For information and requests regarding Duycker Lights,
please contact Duycker’s Chief lighting technician: Heleen Booster – heleen@duycker.nl

Specifications Main Hall

Power:
2 x 32A (3 phase, CEE Red)
1 x 125A (3 phase, CEE Red)

Controller:
Avolites Pearl Expert Pro Titan v9.1

Dimmers:
ETC SmartPack 72 x 2,3kW

Fixtures:
(all fixtures are controlled via Art‐net to DMX)

On Stage:
6 x Robe DL4X Spot (Mode 1)
6 x Vari*Lite VL440 Spot (30ch)
4 x 6‐bar Par 64 (CP61, 1kW NSP)
2 x ACL Par 64
4 x 4‐light blinder
2 x Swefog XEON II Intellahazer
1 x Rosco Smokemachine

Front:
6 x ETC Source 4 Zoom profile (750W)
6 x Robert Julliat Lutin 1KW Fresnell

Hall:
4 x Vari*Lite VL550 Wash (13ch)
8 x 6‐bar Par 64 (CP61, 1kW NSP)

Optional:
2 x Martin Atomic 3kW strobe (4ch)
8 x Floor Par 64 short nose NSP

 

Houserider bands small hall


Houserider bands small hall PDF

Podium Duycker
Raadhuisplein 5
2132 TZ Hoofddorp

Tel: 023-5623310
E-mail: info@duycker.nl

Capacity                                     
Small hall: 250

Max Sound Level
103 dB(A)

Stage                                          
Permanent stage: 8,00 x 3,50 m
Side stage left & right: 1,00 m
Height: 0,80 m

Clearance        
6,00 m

Powersupply                              
CEE-form 2 phase + earth
12 x 2 phase 16 A on stage( 2 x off stage)(Sound)
4   x 2 phase 32 A On stage (Sound)
1 x 32 A CEE (norm IEC 60309) (Light)

Access                                         
Indoor Loadingdock with Dock leveler. Secured parking space for one truck, a single-decker tourbus or 4 medium sized cars. Max vehicle height is: 3.95m (13 ft)

Setup and sound check time
Standard time for setup and soundcheck for the main act is 2 hours before doors. In case of more than one opening act: only the first act will get a quick soundcheck, all other acts will line-check during changeover.

Stagehands
We do not provide stagehands, but we have a very helpful crew that will help you out whenever they can!

Hall expenses
Fixed expenses including; standard house P.A and Lights, standard promotion, standard crew consisting of 1 audio engineer, 1 lighting engineer and standard security.

Payment                                     
Duycker needs a copy of the pasport of all preforming artists to make payment possible.


P.A. Specifications SMALL HALL

Front of House   
1      DiGiCo SD8
1      Lexicon PCM92
1      CD player

Speakers                                                   
4      Lacousitcs ARCS fullrange element
4      SB18i 18” sub

Amplifiers
2      LA4
1      LA8

Monitors                                             
1      DiGiCo SD8
8      Synco CW 152 Floor monitors
1      Synco SW 152 Drum fill
2      Synco Quad Mon Rack
1      Synco Single Mon Rack

Microphones / DI’s 
6      Shure SM58
6      Shure SM57
2      Shure Beta 58
2      Shure Beta 57
1      Shure Beta 87A
1      Shure Beta 91
2      AKG C214
1      AKG D112
1      Neumann KM184
1      AKG C451E
4      Sennheiser E904
1      Sennheiser E815S
3      Sennheiser MD421
6      Radial Pro48 Active
2      Radial ProDI Passive
2      Radial PROAV1
1      Radial Twin Isolator

Light specifications small hall

 

Duycker lightspecs Small Hall 17-01-2017
Patchview Small Hall 17-01-2017

Last edited 18‐01‐2017 (this rider cancels any previous versions)

For information and requests regarding Duycker lights, please contact Duycker’s Chief lighting technician: Heleen Booster – heleen@duycker.nl

Specifications Small Hall

Power:
2 x 32A (3 phase, CEE Red)
1 x 63A (3 phase, CEE Red)

Controller:
Avolites Tiger Touch I Titan v9.1

Dimmers:
ETC SmartPack 36 x 2,3kW

Fixtures:
(all fixtures are controlled via Art‐net to DMX)

On Stage:
6 x Robe DL4X Spot (Mode 1)
4 x High End Color Command (4Ch CMYZ)
4 x Par 64 (CP61, 1kW NSP)
1 x ACL Par 64
2 x 4‐light blinder
1 x Martin Atomic 3kW strobe (4ch)
1 x Swefog XEON II Intellahazer

Front:
4 x ETC Source 4 Zoom profile (750W)
4 x Robert Julliat Lutin 1KW Fresnell

Hall:
8 x Par 64 (CP61, 1kW NSP)

Optional:
8 x Floor Par 64 short nose NSP

 

Cookie

Wij maken gebruik van cookies om je website- bezoek 'slimmer' te maken en omwille van statistieken.

Door op 'OK' te klikken ga je hiermee akkoord.